Cooltron was established in 1998 in California. Cooltron offers:
- DC Brushless Fans. Frame size from 20~172 mm, thickness from 6~55 mm, with variety voltage design of DC 3.3/5/12/24/48V.
- DC Blowers. Various design and voltage range of DC 5/12/24/48V for different applications.
- AC fans and Blowers. AC 110, 220V. 115/230V dual voltage (available for some models)
- Fan Accessories. Guards/Filters/Power Cords
Cooltron fans can be offered as an alternative to ADDA fans, Mechatronics fans, Sunon fans, Comair Rotron fans, Jamicon fans, Orion fans, EBM/Papst fans.
Fan Characteristics:
- Air Flow - The total cubit of flow moved in specified time. Air flow is needed to determine the amount of flow required for heat dissipation.
- Air Pressure - The pressure of the flow while the fan is in static mode. Air pressure is need to determine how much resistance created by the system.
- System Resistance - If the system resistance is small, then a fan with higher airflow and lower air pressure is needed. If the system is large, then a fan with lower airflow and higher air pressure is needed.
- Performance Curve - The performance curve simulates different operating points to bring out the curve by performance test chamber (typically 8 pts).
Fan Mechanical
- Fan blade
- Fan frame
- Bearing
Category of Flow Direction
- Axial - The air flows along and through the shaft direction.
- Blower - The air flows in from the shaft direction and out from the radial direction.
Fan frame
- Standard frame with rib type
- Standard frame with flange type
Bearing Types
- Ball Bearing. Advantages: 1) Suitable for low rpm, 2) high precision, 3) seal type, no oil leakage.
- Sleeve Bearing. Advantages: 1) low cost, 2) easier production.
- Hydraulic Bearing. Advantages: 1) suitable for high rpm, 2) long life span, 3) low vibration.
How to test fans at development stage
- Airflow / Air pressure
- Noise Level
- Electronic Performance (current, lock current, lock temperature, starting voltage, waveform)
- Abnormal noise, vibration
- Reliability test
How to test fans at reliability stage
- Life expectancy test
- High temperature resistance test
- Drop test
- Shock test
- Vibration test
How to test fans at production stage
- Electrical test (current, waveform, starting voltage, speed rpm)
- Abnormal noise
- Fan blade vibration
- 1 hour on/off burn in test and 100% check
- FQC (Finish Quality Control)
- OQC (Outgoing Quality Control)
Cooltron specializes in providing cooling products and services to a wide range of industries. Contact your Competitive Components account representative today as we are a franchise distributor of Cooltron fans.
No comments: